| ◆Type approval by CCS, BV, DNV, and ABS |
| ◆Thermal management solution: air cooling or liquid cooling optional |
| ◆C5 enclosure corrosion protection level, suitable for inland waterways and marine environments |
| ◆Overall system protection rating: IP44, ensuring safe operation of the battery system |
| ◆Independent thermal runaway gas exhaust duct to reduce the risk of fire or explosion in the battery compartment |
| ◆BMS with continuous active balancing to ensure usable system capacity and slow down degradations |
| Item | Rack |
|---|---|
| Cell | LFP310 |
| Certification | DNV |
| Configuration | 1P270S |
| Energy | 267.84kWh |
| Battery Rack Dimensions (W×D×H) | 1110 × 1054 × 3169 mm (liquid cooling) 1110 × 1054 × 2700 mm (air cooling) |
| Nominal Capacity | 310Ah |
| Max. Continuous Charge/Discharge Current | 310 A / 310 A |
| Nominal Voltage | 864VDC |
| Voltage Range | 783–945VDC |
| Weight | 2100 ± 50 kg |
| Communication | CAN / RS485 |
| Safety Design | Explosion-proof valve |
| Thermal Management | Liquid cooling / liquid heating / forced air cooling |
| BMS | Real-time active / passive balancing |
| Start-up Mode | Local + remote start |
| Appearance | Optional decorative panels |
| IP level | IP44 |